New, more sensitive sensor for evaluating drug safety

05 Aug 2017

A new technique for evaluating drug safety can detect stress on cells at earlier stages than conventional methods, which mostly rely on detecting cell death. The new method uses a fluorescent sensor that is turned on in a cell when misfolded proteins begin to aggregate -- an early sign of cellular stress.

The method can be adapted to detect protein aggregates caused by other toxins, as well as diseases such as Alzheimer's or Parkinson's. A paper describing the new method, by a team of researchers at Penn State University, appears in the journal Angewandte Chemie International Edition.

"Drug-induced protein stress in cells is a key factor in determining drug safety," says  Xin Zhang, assistant professor of chemistry and of biochemistry and molecular biology at Penn State, the senior author of the paper. "Drugs can cause proteins - which are long strings of amino acids that need to be precisely folded to function properly - to misfold and clump together into aggregates that can eventually kill the cell. We set out to develop a system that can detect these aggregates at very early stages and that also uses technology that is affordable and accessible to many laboratories."

The new system is the first to use a fluorescent sensor that is not turned on until the misfolded proteins begin to aggregate. The researchers designed an unstable protein - called AgHalo - that is tagged with a special fluorescent dye that becomes active in a hydrophobic, i.e. water-repellent, environment.

Hydrophobic portions of proteins are usually buried deep in the structure of a properly-folded protein because the environment of the cell is mostly water. When the AgHalo protein begins to misfold and aggregate the dye can interact with the hydrophobic portions of the protein and begin to fluoresce.

Previous systems used sensors that were always on. The cells would have a general diffuse fluorescence prior to any stress and the systems could only detect proteins stress when the misfolded proteins aggregated, forming brighter spots of fluorescence that were large enough to be seen under a microscope.

"An additional advantage of our system is that the level of fluorescence is correlated to the amount of protein aggregation in the cell, so we can quantify the level of stress" says Yu Liu, a postdoctoral researcher at Penn State and the first author of the paper. "Also, because our method measures the level of fluorescence, rather than having to identify the fluorescence under a microscope, it can be done using more accessible technology, like plate readers, and it is much more high-throughput."

The researchers used their sensor to test the level of protein stress caused by five commonly-used anti-cancer drugs. Although none of the drugs they test cause significant cell death in previous drug safety tests, all five produced some level of protein stress detectable by the AgHalo sensor.

"Because we tested the anti-cancer drugs at much higher doses than typically used for treatment, our results do not necessarily call into question the continued use of these drugs," says Liu. "However, because protein stress from long-term treatments could have lasting effects, evaluating drugs with our new sensor will help in the development of safer drugs."

Protein stress can be induced by other many factors. Heat, toxins, bacterial infections, cancer, and even ageing can cause proteins to misfold and form aggregates in cells. "With our method, we can quantitatively detect protein stress in cells at much earlier stages and therefore researchers can begin to study the mechanisms that cells use to combat this stress and develop compounds that can enhance the cell's ability to handle protein stress," said Zhang.